Some assemblies cause a Soldi Edge crash on open.

Platforms
  • na windows-1032
Release Versions
  • Solid Edge V222.0
Solution

The assemblies that would not open contained vendor components downloaded from the vendor's website. The item revisions for the components in Teamcenter contained datasets with no named reference. How the item revisions got into that state is unknown. Teamcenter would not allow a named reference to be added to the dataset.

To resolve the issue the user had to delete the existing dataset and create a new one, then add the named reference. Once this was done the assemblies containing the components opened without issue.