NX The NX customer default UGMGR_SeedPartName specifies a title which does not exist in Teamcenter

2024-07-08T12:13:05Z
NX for Design

Summary


Details

When opening an Item Revision that has no NX dataset from Teamcenter into NX, the open operation is successful but is accompanied by following warning message:


What is the meaning of this message and how to eliminate it?

Solution

This is due to the value specified in Customer Defaults for Default Seed Part does not exist under the required folder location inside Teamcenter.

For example:
With the following Customer Defaults setting, notice the value for Default Seed Part is an existing Item that is currently under the Newstuff folder, which is not under the required folder of infodba:Unigraphics seed parts/master


The above configuration will trigger the warning to popup.

To eliminate the warning: Copy the Item specified by Customer Defaults and paste it into infodba:Unigraphics seed parts/master folder:


KB Article ID# PL8799131

Contents

SummaryDetails

Associated Components