NX Unable to create Symbolic Thread in Customized NX

2023-12-29T10:29:31Z
NX for Design

Summary


Details

While launching the Thread dialog inside NX, no dialog being displayed, and in the log file, below error is traced.

+++ Thread standard data not found. Check standards data installation.

The user has upgraded to NX2306 and has set the Hole standard variables to his below custom standard files.

  1. nx6.0_Drill_Size_Hole_Standard.xml
    1. nx502_Screw_Clearance_Hole_Standard.xml
      1. nx502_Threaded_Hole_Standard.xml
        Solution

        From NX1926 onwards:

         "nx502_Threaded_Hole_Standard.xml" standard file has been replaced by "NX_Thread_Standard.xml" file.

        From NX 2206 onwards,  "nx6.0_Drill_Size_Hole_Standard.xml" has been replaced by  "NX_Drill_Size_Hole_Standard.xml"

        Similarly "nx502_Screw_Clearance_Hole_Standard.xml" has been replaced by "NX_Screw_Clearance_Hole_Standard.xml" file.

        So in NX2306, the user has to replace his earlier custom standard files with the above files and need to modify the respective standard files to enter his custom values.

        Please refer to the below documentation.

        https://docs.sw.siemens.com/en-US/doc/209349590/PL20221117716122093.modeling/hole_adv_hole_feat_tables_screw_rt

        Please refer to the below documentation related to modifying/entering the custom values to these standard files.

        https://docs.sw.siemens.com/en-US/doc/209349590/PL20221117716122093.modeling/xid2213342

        https://docs.sw.siemens.com/en-US/doc/209349590/PL20221117716122093.modeling/xid2213352

        https://docs.sw.siemens.com/en-US/doc/209349590/PL20221117716122093.modeling/xid2213347

        KB Article ID# PL8766349

        Contents

        SummaryDetails

        Associated Components

        Modeling