NX Interpart Expressions and Revision Control when using Allow Multiple Revisions

2023-08-29T13:48:00Z
NX for Design

Summary


Details

When opening parts containing interpart expressions, the interpart expressions are referencing the incorrect revision of the source part and the values for the expressions are not correct for that revision.  This only happens when Multiple Revision are allowed in the NX Teamcenter Integration customer defaults.

How does this situation arise, then how can it be corrected and avoided in the future?

Solution

As demonstrated in the video. The part used as the source for interpart expressions should always be revised with the referencing components and assembly fully open in the session. Failure to do this can result in the source for the interpart expression being incorrect when the assembly is reopened and incorrect values being used.

KB Article ID# PL8735319

Contents

SummaryDetails

Associated Components

Assemblies Modeling Teamcenter Integration for NX