NX About first digits in 'Unlocked NX Configuration Variables' in NX syslog.

2023-07-04T06:38:20Z
NX for Design

Summary


Details

If you open NX syslog file and search for "Unlocked NX Configuration Variables", you will find the information as below.

************** Unlocked NX Configuration Variables **************

[13] AEROSTRUCTURES_APP_DIR C:\Siemens\NX\NX2212\simulation\aerostructures

[37] ALP_APP_DIR C:\Siemens\NX\NX2212\manufacturing_planning\assembly_line_planner

[55] ANIMATION_DESIGNER_APP_DIR C:\Siemens\NX\NX2212\mechatronics\animation_designer

[15] AUTOMATION_DESIGNER_APP_DIR C:\Siemens\NX\NX2212\automation_designer

[65] AUTOMOTIVE_APP_DIR C:\Siemens\NX\NX2212\ugautomotive;C:\Siemens\NX\NX2212\ugautomotive\bodydes;C:\Siemens\NX\NX2212\ugautomotive\diedes;C:\Siemens\NX\NX2212\ugautomotive\dieeng;C:\Siemens\NX\NX2212\ugautomotive\packaging

[3] AUTOSTAMPING_DATA_DIR C:\Siemens\NX\NX2212\ugautomotive\diedes

[60] CABLEROUTER_APP_DIR C:\Siemens\NX\NX2212\nxcablerouter

[29] CAE_SIMULATION_DIR C:\Siemens\NX\NX2212\simulation

[56] CAM_APP_DIR C:\Siemens\NX\NX2212\mach

[6] CMM_INSPECTION_APP_DIR C:\Siemens\NX\NX2212\cmm_inspection

[26] COMPOSITES_APP_DIR C:\Siemens\NX\NX2212\composites

[48] DESIGNSPACEEXPLORER_APP_DIR C:\Siemens\NX\NX2212\designspaceexplorer

[59] DESIGN_TOOLS_APP_DIR C:\Siemens\NX\NX2212\design_tools

[39] DIAGRAMMING_DIR C:\Siemens\NX\NX2212\diagramming

[7] DMU_APP_DIR C:\Siemens\NX\NX2212\ugii\dmu

[41] DRAFTING_APP_DIR C:\Siemens\NX\NX2212\drafting

[3] DXFDWG_DIR C:\Siemens\NX\NX2212\dxfdwg\

[3] EDIEWIZARD_DIR C:\Siemens\NX\NX2212\stamping_tools\ediewizard

[3] EDIEWIZARD_LIB_DIR C:\Siemens\NX\NX2212\stamping_tools\ediewizard

[3] ELECTRODE_DESIGN_DIR C:\Siemens\NX\NX2212\moldwizard\electrode

What do the numbers [13], [37], [55], [15], [65], [3], [60], [29], [56], [6], [26]..etc. mean?

Solution

These numbers tell you where the value came from – if you look after all the variables and values you will see a legend mapping these numbers to locations.

If you search “Variable locations” in NX syslog file, you will get the number v/s file name mapping.

Variable locations:

[1] System Environment

[2] Set internally

[3] C:\Siemens\NX\NX2212\ugii\ugii_env_ug.dat

[4] Registry

[5] C:\Siemens\NX\NX2212\MBD\manifest\mbd_env.dat

[6] C:\Siemens\NX\NX2212\CMM_INSPECTION\manifest\cmm_inspection_env.dat

[7] C:\Siemens\NX\NX2212\UGII\manifest\dmu\dmu_env.dat

[8] C:\Siemens\NX\NX2212\UGII\manifest\implicit_modeling\implicit_modeling_env.dat

[9] C:\Siemens\NX\NX2212\STAGE_MODEL\manifest\StageModel_env.dat

[10] C:\Siemens\NX\NX2212\NXAECDESIGN\manifest\AECDesign_env.dat

[11] C:\Siemens\NX\NX2212\FABRICMODELER\manifest\fabricmodeler_env.dat

[12] C:\Siemens\NX\NX2212\NXCOATINGS\manifest\Coatings_env.dat

[13] C:\Siemens\NX\NX2212\SIMULATION\manifest\aerostructures\aerostructures_env.dat

[14] C:\Siemens\NX\NX2212\DIAGRAMMING\manifest\symbol_designer_env.dat

[15] C:\Siemens\NX\NX2212\AUTOMATION_DESIGNER\manifest\AutomationDesigner_env.dat

KB Article ID# PL8721081

Contents

SummaryDetails

Associated Components

Modeling