NX MCD connection error (Runtime error)

2023-09-14T09:56:31Z
NX for Design

Summary


Details

Mechatronics Concept Designer (MCD) Simulation failed with a Runtime error. The connection to CMVM seems to be the cause. 

Signal Connection was correct again after changing the application from MCD to (e.g.) Gateway and back to MCD. This workaround is not applicable when running MCD player.

Platforms
  • na windows-1064
Release Versions
  • NX V2027
Solution

Set following Mechatronic Concept Designer Parameters to solve this behavior:  

Mechatronics Concept Designer Preferences --> Sequence Editor --> Automatic Deactivate Operations = OFF 


Now the operations whose referencing runtime parameters have signals mapped with external signals, will not be disabled automatically anymore.

Notes

KB Article ID# PL8721025