NX TC_NX_CGM_create_pattern not indexing each CGM dataset correctly

2022-08-02T21:12:33Z
NX for Design

Summary


Details

Per instruction found in NX2206 documentation below, the TC_NX_CGM_create_pattern result is not working.

https://docs.sw.siemens.com/en-US/product/209349590/doc/PL20200605195244930.tcint/html/xid1972498

After setting the TC preferences as such:

TC_NX_CGM_create_pattern = ${ItemID}_${RevisionID}-SH-{1:2}

And execute "File > Export > PDF" in NX by using option "Export as separate CGMs", the sheet number of CGM datasets are not indexing correctly:


Solution

The correct value for the TC preference should be:

TC_NX_CGM_create_pattern = ${ItemID}_${RevisionID}-${SheetName}-{1:2}


KB Article ID# PL8663956

Contents

SummaryDetails

Associated Components

Teamcenter Integration for NX