Solid Edge Setting UGII_CAM_RESOURCE_DIR to resource folder leads to invalid configuration error.

2022-01-31T21:15:04Z
APPLICATION

Summary


Details

Setting UGII_CAM_RESOURCE_DIR to resource folder leads to invalid configuration error.



Solution

If UGII_CAM_RESOURCE_DIR is overridden with a system environment variable, the path needs to contain a back slash at the end, otherwise you will get an "Invalid configuration file" error after launching CAM Pro from Solid Edge and activating the Manufacturing environment.


Let's say that you create a folder C:\MyMACH and copy the entire "resource" folder from "C:\Program Files\Siemens\Solid Edge CAM Pro 2007\MACH" to C:\MyMACH. The System variable name UGII_CAM_RESOURCE_DIR should have a value "C:\MyMACH\resource\". Please include the back slash at the end. 



Notes and References


Hardware/Software Configuration

Platform: INTL64
OS: windows
OS Version: n/a
Product: SOLID_EDGE
Application: SE_CAM_PRO
Version: V222.0
Function: OPEN_FROM_SE

Ref: 001-10246143

KB Article ID# PL8605849

Contents

SummaryDetails

Associated Components

APPLICATION: SE_CAM_PRO