When Process Designer client trying to login, got error: "login failed. cannot obtain message.  Formatmessage failed"

What does this error mean and how to address the issue?

Solution

Normally this error is due to the error setup/installation of eMclient.

When Process Designer/Process Simulate client(eMclient) installed, we can find component service like this: 

  components > my computer > DCOM config > eMserver

  components > my computer > DCOM config > eMclient

But in this case customer selected eMserver during client installation, or customer has installed different version of Tecnomatix/eMserver, from client machine, we

can find components service like this:

  components > my computer > COM+ application > eMserver 

     (above component should not be exist from eMclient machine)

  components > my computer > DCOM config > eMserver

  components > my computer > DCOM config > eMclient

This cause the error when startup Process Designer/Process Simulate client.  After manually deleting "COM+ application, eMserver ", the issue has been addressed.