NX Ray Traced Studio visualization error

2021-10-06T23:28:00Z
NX for Design

Summary


Details

Ray Traced Studio rendering is comming up with an Error


InvalidObjectException ============================= 
*** EXCEPTION: Error code 4235004 in line 3175 of E:\workdir\REF\1926.1700\src\lwks2\no\ind\sh_Session.cxx at Wed Jun 9 16:08:42 2021 Mitteleuropäische Sommerzeit 
+++ Unable to render Ray Traced Studio display. 
Lightworks Author2 invalid object. 



Solution

The variable NX_RTS_IRAY = 0 will cause NX to use the older version of Ray Traced studio (Author2 engine) for processing the rendered images. 
Removing this environement or set it to 1 will solve the issue. 



Notes and References


Hardware/Software Configuration

Platform: all
OS: n-a
OS Version: n-a
Product: NX
Application: SYSENG
Version: V1942
Function: VISUALIZATION

Ref: 001-10079489

KB Article ID# PL8549881

Contents

SummaryDetails

Associated Components

Modeling