NX
Some alerts show up if you try to edit a thread
2021-10-06T23:27:52Z
NX for Design
Summary
Details
Some alerts come up if you try to edit Thread feature after executing "Pocket" function in Mold Wizard. The issue is occurring in "Symbolic Thread" feature, but the cause of the issue seems to be related to MW Cooling Standard Library.
Step to reproduce:
1.Prepare for a box and a simple hole Example > Box = 100x100x100, hole diam =10mm 2.Mold Wizard > Cooling Standard Part Library Example, choose PIPE_THREAD=1/4 > OK
3. Move the comp to top of the box.
4.Put a pocket by Pocket function.
5.Select NX1926 comp in ANT > Make Work Part 6.IN PNT, select "1/4 Symbolic Thread" as "PIPE_THREAD" > Edit with Rollback
Solution
The issue is fixed in NX1980.
Work around:
The suggestion is , change the RadialEngage="Custom" to RadialEngage="Standard",(before creating pocket) and NX thread will support to edit it.
The default value RadialEngage="Custom" in NX_Thread_Standard.xml for the "HB247" type (file is under directory \wntx64\kits\ugii\modeling_standards\ ), and NX thread function filters such type of threads, so if we edit it in NX thread dialog ,the messages you mentioned show up. You can see HB247 cannot be found in the Thread Standard area.
Hardware/Software Configuration
Platform: INTL64 OS: windows OS Version: 1064 Product: NX Application: KDA Version: V1953 Function: MOLDWIZARD