NX NX Multiple versions configuration

2021-10-06T23:27:46Z
NX for Design

Summary


Details

After installing a new version of NX, on a workstation where multiple versions of NX
are installed, you may have the feeling that it is not a fresh installation at startup or receive
message that NX has failed to read a customer default setting

Solution

Starting NX 1872 Series, when NX starts and does not find an existing local configuration
directory, it will copy all the settings from the older version when available

eg:

if C:\Users\currentuser\AppData\Local\Siemens\NX1872 is not found

C:\Users\currentuser\AppData\Local\Siemens\NX1847 will be copied to

C:\Users\currentuser\AppData\Local\Siemens\NX1872

This directory includes Favorites, History, Customer Defaults, Roles...

Hardware/Software Configuration

Platform: all
OS: n/a
OS Version: n/a
Product: NX
Application: GATEWAY
Version: V1872
Function: CUSTOMER_DEFS

Ref: 002-8513953

KB Article ID# PL8513953