NX Post Processing non-consecutive operations

2021-10-06T23:27:46Z
NX for Manufacturing

Summary


Details

What–s New documentation from NX1872, and help documentation in NX 1930, mention the ability to postprocess non-consecutive operations:

https://docs.sw.siemens.com/en-US/product/289054037/doc/PL20190725124833894.whatsnew/html/xid1660714

But still NX prompts error "Operations selected are not in consecutive order" and post processing fails. 

But how do I enable it?



Solution

Until NX 1953, this has to be enabled by an environment variable:

UGII_CAM_POST_ENABLE_NON_CONSECUTIVE_OPERATIONS=1 

Add this variable to your NX\UGII\ugii_env.dat



Notes and References


Hardware/Software Configuration

Platform: all
OS: n/a
OS Version: n/a
Product: NX
Application: CAM
Version: V1930
Function: POSTPROCESS

Ref: 001-9858215

KB Article ID# PL8513826

Contents

SummaryDetails

Associated Components

Manufacturing Post Builder