Simcenter 3D Solutions DPBLKTOL = 0.0 to have the software ignore duplicate GRID point IDs

2021-10-06T23:27:45Z
Simcenter 3D

Summary


Details

Set DPBLKTOL = 0.0 to have the software ignore duplicate GRID point IDs 

and/or coordinate system definitions and proceed with the solve.

In solving / ignoring, please explain what is done concretely.

For example: Does the node described earlier in bulk data have priority? 

Does the nodal point described later take precedence?

Which way can be solved in the above example?

Solution

The duplicate grid ids i.e the ones which are defined later are ignored.

The node described earlier in bulk data have priority.

Notes

KB Article ID# PL8513572

Contents

SummaryDetails

Associated Components

Acoustics Additive Manufacturing Assembly FEM Correlation and Updating Durability Electromagnetics (High Frequency) Electromagnetics (Low Frequency) Flexible Pipe Laminate Composites Margin of Safety Motion Multiphysics NX Open Nonlinear Optimization Pre/Post Response Dynamics Rotor Dynamics Samcef Environment Simulation Process Management Thermal / Flow