Details
When turning an internal diameter, verification with collision check may give a false collision warning.
Solution
The problem occurs when 'Tool Display' is set to 'Tool'
As a workaround, switch 'Tool Display' to 'Assembly', and then no collision is detected.
Notes and References
PR 9816426
Hardware/Software Configuration
Platform: INTL64
OS: windows
OS Version: 10_1507
Product: NX
Application: CAM
Version: V1919
Function: TURNING
Ref: 001-9816426