Tecnomatix Quality Management DPV: Configuration Explorer error

2021-10-07T00:01:53Z
Dimensional Planning Validation CMM/DMIS

Summary


Details

After installing DPV_ETL, when invoking the "DPV Enterprise Configuration Explorer", a message pops-up that states the following: "Access to path E:\Siemens\DPVETLENT\Applications\DPV\TaskConfig.xml" is denied. 

When attempting to make a change to a panel in the "DPV Enterprise Configuration Explorer" and then attempt to save, receiving a security window from Iexplore.exe which demands my credentials. Upon entering my valid credentials (and my credentials are in the Administrators group on the server), nothing happens. 



Solution

Do these two things in IE settings:

1. Add localhost into trusted sites



2. In User Authentication -> Logon -> check option for: Automatic logon with current username and password




Notes and References


Hardware/Software Configuration

Platform: INTL64
OS: windows
OS Version: 2016
Product: TECNOMATIX
Application: QUALITY
Version: V12.2.0.8
Function: DPV

Ref: 001-9769875

KB Article ID# PL8506464

Contents

SummaryDetails

Associated Components

3D Measurements Enterprise Foundation Package Graphical Report Automation Graphical Report Viewer Historical Report Viewer Inspection Devices Lite Foundation Package Reporting & Analysis Single Part Reporting