setting equivalent viscous damping in Response dynamics like in SOL109,112

Solution

Critical damping in Nastran is the same as viscous damping in Simcenter Response Dynamics.  The overall structural "G" damping is Nastran (in simcenter interface SOL 109 bulk section; sol 112 case section  ) is just a different unit of damping so G=0.04 is the same as CRIT=0.02. 

Notes

KB Article ID# PL8171088

Contents

SummaryDetails

Associated Components

Acoustics Additive Manufacturing Assembly FEM Correlation and Updating Durability Electromagnetics (High Frequency) Electromagnetics (Low Frequency) Flexible Pipe Laminate Composites Margin of Safety Motion Multiphysics NX Open Nonlinear Optimization Pre/Post Response Dynamics Rotor Dynamics Samcef Environment Simulation Process Management Thermal / Flow