Details
_inst" will be appended to sub-assembly JT file name when exported from NX.
How to not append "_inst" to JT file name of sub-assembly.
Solution
1. Create an NX assembly having a sub-assembly.
2. Add the sub-assembly multiple times into assembly. That is have many instances in assembly.
3. If export the assembly as JT "_inst" will be appended to the JT file name of sub-assembly.
If you do not want to append "_inst" to JT file name of sub-assembly, then set the below environment variable.
UGII_PV_NO_SUBASM_INSTANCE_JT=1
But note that if the 'Reference Set' of the instances of sub-assembly is different, then "_inst" will always be appended to JT file name of sub-assembly.
Hardware/Software Configuration
Platform: all
OS: n/a
OS Version: n/a
Product: NX
Application: TRANSLATOR
Version: V12.0.2
Function: NX_JT
Ref: 002-8016488