A native Solid Edge model with two revisions is imported to Teamcenter with the Add to Teamcenter utility. After import, the items with revisions are created, but the sequence of item revisions are reversed. For example, item 03130322-01 with two revisions, 01 and 02 with 02 as the latest revision when imported to Teamcenter, displays the item revisions in the sequence 03130322-01/02 and 03130322-01/01. How can this be controlled?
Solution
The Add to Teamcenter bulkload tool does not support multiple revisions of a Solid Edge file . It is recommended to load the last revision only.
Please review the documentation on how to cleanup and prepare your legacy data before bulkloading to Teamcenter:
http://docs.plm.automation.siemens.com/tdoc/se/2019/se_help#uid:xid1129777:xid1329553:index_managing_documents:xid599335Hardware/Software Configuration
Platform: all
OS: n/a
OS Version: n/a
Product: SOLID_EDGE
Application: DOC_MANAGEMENT
Version: V219MP7
Function: DATA_PREP
Ref: 002-8014442