NX Wrong visualization at Turning Verify, Groove Operations

2021-10-06T23:27:22Z
NX for Manufacturing

Summary


Details

Tool Path Visualization 'Replay' of a Turning Grooving operation gives incorrect 2D material removal. (material shows the offset by 2 x the tool radius)



Solution

The problem is fixed in NX 1863 - May 2019 Monthly Update (NX 1847 Series) 
A workaround in NX 12.0.2 is to toggle the Tool Display to 'Assembly' (without stepping through the operation) and back again to 'Part'.
This clears the problem. 



Notes and References


Hardware/Software Configuration

Platform: INTL64
OS: windows
OS Version: 1064
Product: NX
Application: CAM
Version: V12.0.2
Function: TURNING

Ref: 001-9502609

KB Article ID# PL8014281

Contents

SummaryDetails

Associated Components

Manufacturing General