NX Measure results sent to Information window will not display

2021-10-06T23:27:21Z
NX for Design

Summary


Details

When using the new Measure function, no Information window will display when checking the option, 'Show Results in Information Window' while measuring the mass or weight of the solids in an Assembly.

Solution

To get the Mass/Weight results of an Assembly sent to the Information Window: 
  1. On the Measure dialog under the Objects to Measure group, toggle on 'Object Set'.
  2. Set the Result Filter to:  Body (0)
  3. In the Selection toolbar set the Type Filter to 'Solid Body'.
  4. Drag a window around the components in the Work Area to select them.
  5. 'Apply' the dialog.
The Information Window will display with the mass/weight and related data on all the solids selected.



Notes and References


Hardware/Software Configuration

Platform: all
OS: n/a
OS Version: n/a
Product: NX
Application: DESIGN
Version: V12.0.2
Function: INFO_ANALYSIS

Ref: 001-9495258

KB Article ID# PL8014170

Contents

SummaryDetails

Associated Components

Modeling