Simcenter 3D Solutions Duplicate point names in an assemgly fem

2019-05-08T17:39:25Z
Simcenter 3D

Summary


Details

--------------- 

When I start an NX thermal or flow solution I get this error: 

ERROR

Duplicate named points have been specified. Reference to 

named points is invalid when duplicate names are specified.

Solution

 In a fem, points can be named using Edit, Properties. NX thermal and flow 

solutions will fail with the above error if more that one point in a fem has 

the same name, or if different component fems in an assembly fem have points 

with the same name.

Assembly label manager does not currently rename points, so the user must 

rename them manually using Edit, Properties.

Notes

KB Article ID# PL8010677

Contents

SummaryDetails

Associated Components

Acoustics Additive Manufacturing Assembly FEM Correlation and Updating Durability Electromagnetics (High Frequency) Electromagnetics (Low Frequency) Flexible Pipe Laminate Composites Margin of Safety Motion Multiphysics NX Open Nonlinear Optimization Pre/Post Response Dynamics Rotor Dynamics Samcef Environment Simulation Process Management Thermal / Flow