NX NX CMM Inspection - Ignoring (does not recognize) collisions

2019-11-04T08:53:33Z
NX for Manufacturing

Summary


Details

Simulation with collision check. Collision check was ignored without warning



Solution

 Problem was due to machine definition:


NX\CMM_INSPECTION\resource\library\machine\ascii\insp_machine_database.dat


Machine definition had '/' special characters :


DATA | Zeiss Accura II 9/14/8 | 5 | 3 Axis gantry CMM | DMIS | Zeiss etc.....


This was allowing simulation, but caused collisions to be ignored


The '/' characters were removed and this resolved the problem


DATA | Zeiss Accura_II_091408 | 5 | 3 Axis gantry CMM | DMIS | Zeiss etc...