NX Unable to stop ISV simulation at limit violation.

2019-11-01T13:38:04Z
NX for Manufacturing

Summary


Details

ISV Simulation


Simulation Settings has 
'Stop on Limit Violation' toggled ON 
'Check for Limit Violation' toggled ON


The simulation does not stop at the programmed limit violation. 
(but a limit violation is reported in the Information window).



Solution

 This can happen if the 'Don't display this message again' has previously been toggled in the 'Limit Violation' message.


This can be rest by 'Preferences - user interface' - 'Reset "Don't display this message again"



Notes and References


Hardware/Software Configuration

Platform: INTL64
OS: windows
OS Version: n/a
Product: NX
Application: CAM
Version: V10.0.2
Function: ISV

Ref: 001-7558759

KB Article ID# PL8010512