When attempting to create a new NX part file the error "Unable to load 
preferences values file" is raised.



Solution

 One of the reasons this error can be raised, is if a legacy User, Group or 
Site dpv file is imported into the NX Customer Defaults and it references a 
a Drafting Standard file that does not exist in the current configuration.


To fix this, open the dpv file in an editor and remove the line that reads;


 <Pref Tab="Standard" name="Drafting_Standard" title="Drafting 
Standard"...etc.


Save the file and restart NX.