Details

A user is creating flexible hoses with the same length but which can be 
routed differently.  The hose is created with the frame utility.


By default Teamcenter will generate a different Find no. in the Teamcenter Structure 
Manager, but in this case the user wants to have the same Find.no for both parts.  
How can this be done?



Solution

The Teamcenter preference SEEC_Synchronize_ItemNumbers is controlling this 
behavior. 


If you have two identical frame parts and you want to see this as a packed 
Find no there is an option in this preference you can use: 


/UniqueBasedOnCutLength=0 


When you set this option both hoses will get the same Find no.