CAM Express button is grayed out in Solid Edge ST10.




Solution

NX 11.0.2 mp13 is able to open Solid Edge ST10 files. Earlier NX Maintenance Packs required manual replacement of plmxmlAdapterSE70.dll. It is no longer needed to do that, since NX is already in synch with Solid Edge ST10.

If you are unable to update to NX 11.0.2 mp13 and the NX 11.0.2 mp that you have is unable to open Solid Edge ST10 files, you may try the following:

1. Download  'Solid Edge-> Product updates -> ST10 -> Plmxml -> V110.zip'  from the GTAC web site:


https://download.industrysoftware.automation.siemens.com/


2. Extract VS2013 -> 64Bit ->plmxmlAdapterSE70.dll'


3. Backup the existing 'C:\Program Files\Siemens\NX 11.0\NXBIN\ plmxmlAdapterSE70.dll'. Path maybe different.


4. Copy the plmxmlAdapterSE70.dll you downloaded to the NXBIN folder.


5. Open a command prompt window. Run it as administrator.


6. Cd C:\Program Files\Siemens\NX 11.0\NXBIN


7. Type "regsvr32 NXCam_64.dll" in the cmd prompt window to register this DLL.


8. The Cam Express button should be enabled now.