Naming failures while exporting the assembly outside teamcenter

·        Under Export Assembly window go to "Naming" tab 
·        Click on "Define Naming Rule"
·        Under "Naming Rule" window select the "Rename" Option
·        Under Add/Replace/Rename String enter the naming rule as ${ID}${Revision}DRG and click Ok
·        Execute the export


 Naming Failures error occurs.

Solution

Change the "Add/Replace/Rename String" field

From ${ID}${Revision}DRG to "${DB_PART_NO}${DB_PART_REV}DRG"

Hardware/Software Configuration

Platform: INTL64
OS: window
OS Version: 1064
Product: NX
Application: NXMANAGER
Version: V12.0.2
Function: CLONE_EXPORT

Ref: 002-8008681

KB Article ID# PL8008681