NX Datum plane in NX unable to view in JT

2021-10-06T23:26:37Z
NX for Design

Summary


Details

Datum plane in NX part file cannot be viewed in JT file after opening the same JT in Teamcenter Visualization.

Solution

Datum Planes can be exported to the JT file format by setting "activateCsysPMI=true" in the tessUG.config file.
 
So update the tessUG.config accordingly and export the JT. Once the JT is exported open the same in Teamcenter Visualization and enable the PMI to view the Datum Planes in TC Vis.

Notes and References

9386644



Hardware/Software Configuration

Platform: INTL64
OS: window
OS Version: 764SP1
Product: NX
Application: TRANSLATOR
Version: V11.0
Function: NX_JT

Ref: 002-8008573