NX Reflect Component function is not found by command finder

2021-10-06T23:26:34Z
NX for Design

Summary


Details

When running NX12 modelling application. A search in command finder on "Reflect Component" renders in:
-----------------------------
Reflect Component Creates new component with reflection transforms. This command is available in the Gateway application.
-----------------------------

Change application in NX to Gateway a search in command finder on "Reflect Component" renders in:
-----------------------------
Reflect Component Creates new component with reflection transforms. This command is not available.
-----------------------------

Why is it not available?



Solution

The access to the NX command "Reflect Component" is controlled by a NX customer default.
Assemblies --> Site Standards, Miscellaneous tab, Assembly Reflection group Reflect Component: "Disable" is default value.
Other possible values are "Display Only" and "Display and Create", which will make the command available in NX.