Solid Edge Only one named view in a model can be used to change a draft view display.

2021-10-06T23:53:48Z
DRAFT

Summary


Details

Cannot change an already placed Named View with another Named View in Solid Edge 2019 Draft.



Solution

Remove Unigraphics Solutions from HKEY_CURRENT_USER/Software in the registry editor.  This is a left over entry from a previous version of Solid Edge.



Notes and References


Hardware/Software Configuration

Platform: INTL64
OS: window
OS Version: 1064
Product: SOLID_EDGE
Application: DRAFT
Version: V219MP4
Function: DRAWING_VIEWS

Ref: 001-9351529