Solid Edge Enable SE part list syncing with find No property in Teamcenter to get 1,2,3.

2021-10-06T23:53:04Z
DOC_MANAGEMENT

Summary


Details

While importing an Assembly using "Add to Teamcenter" option,  in Teamcenter find number is creating new number as 10,20,30... instead of 1,2,3 (Part list).



Solution

To enable SE part list syncing with find No property in Teamcenter to get 1,2,3 set following:
 SEEC_BOM_Synchronize=TRUE
 SEEC_Synchronize_ItemNumbers=TRUE 
 and add values " /Start=1" , "/Increment=1" (multiple values).






Hardware/Software Configuration

Platform: INTL64
OS: window
OS Version: 764
Product: SOLID_EDGE
Application: DOC_MANAGEMENT
Version: V110.0
Function: SEEC

Ref: 002-8006290