NX X After export, some of components having different naming convention i.e. PartName_Rev_1 instead of PartName_Rev.

2021-10-06T23:26:25Z
NX for Design

Summary


Details

After exporting Assembly Outside Teamcenter, some of components having different naming convention i.e.  (PartName_Rev_1) instead of (PartName_Rev).



Solution

Export utility append "_n" if the exported name is duplicate. After applying the naming scheme, if name found to be duplicate then it will append.
If you don't want the duplicate names to be renamed then you can set "UGII_UGMGR_DUPLICATE_NAME_CHECK=true" which report the duplicate names which we can fix up.

Notes and References

9115806 

Hardware/Software Configuration

Platform: INTL64
OS: window
OS Version: 764SP1
Product: NX
Application: NXMANAGER
Version: V11.0.2
Function: CLONE_EXPORT

Ref: 001-9115806

KB Article ID# PL8004881