NX Cannot get the correct status of the license server with LMTools

2021-10-06T23:26:21Z
NX System Administration

Summary


Details

Cannot get the correct status of the license server with LMTools when selecting,  'Server Status-> Perform Status Enquiry'.

The utility is reporting the status of both the Siemens PLM license server and the license server for an unrelated product, (in this case ANSYS), even though the 'Siemens PLM License Server' is the service selected.



Solution

In the LMTools utility-> Service/License File <tab>, select  the checkbox, "LMTools ignores license file path environment variables".
If you query the license server again, it should now report the status of the Siemens PLM License Server, if this is the service selected.



Notes and References





Hardware/Software Configuration

Platform: INTL64
OS: window
OS Version: 764
Product: NX
Application: SYSTEM
Version: V12.0
Function: WNT_OS_ISSUES

Ref: 001-9198380

KB Article ID# PL8004485

Contents

SummaryDetails

Associated Components

Installation