NX X Unable to start NX if UGII_ROOT_DIR is not set in BCT batch file

2021-10-06T23:27:01Z
NX for Design

Summary


Details

--------------- 
Unable to start NX in managed mode in machines where Space pilot (PRO) driver 
is installed if UGII_ROOT_DIR is not set in eoms_set.cmd BCT file



Solution

 The driver for the 3DConnexion-Device integrates in the NX-GUI. The LCD- 
Manager from 3DConnexion forced NX to crash.


To start NX without crash, disable environment variable UGII_3DCONNEXION_DIR.



Notes and References

8949759



Hardware/Software Configuration

Platform: INTL64
OS: windows
OS Version: 1064
Product: NX
Application: NXMANAGER
Version: V12.0.2
Function: STARTUP

Ref: 002-7009849

KB Article ID# PL7009849

Contents

SummaryDetails

Associated Components

Teamcenter Integration for NX