In random analysis when evaluating fatigue sometimes the LCR Level Crossing 

Rate is important. What are the units of LCR?

Solution

 The units are number of crossings per unit time, such as cycles per second, or 

Hertz.

Notes

IR 7687524.

KB Article ID# PL7008925

Contents

SummaryDetails

Associated Components

Acoustics Additive Manufacturing Assembly FEM Correlation and Updating Durability Electromagnetics (High Frequency) Electromagnetics (Low Frequency) Flexible Pipe Laminate Composites Margin of Safety Motion Multiphysics NX Open Nonlinear Optimization Pre/Post Response Dynamics Rotor Dynamics Samcef Environment Simulation Process Management Thermal / Flow