NX How to merge two specification datasets into one

2021-10-06T23:27:03Z
NX for Design

Summary


Details

Currently under an item revision, there are two specifications created from the same UGMaster. How to merge two specification datasets into one?



Solution

1. Load Specification_1 using "Component Fully Load" load option
 
2. Execute "File > Export > Part" using following options: 
- Part Specification = Existing 
- Specify Part = browse and select the UGMaster dataset 
- Drawing Selection = highlight the drawing sheet 
- OK the dialog to proceed with export 

3. Save all files and close all files. 

4. Load Specification_2 using "Component Fully Load" load option 

5. Make UGMaster the Display Part. Notice sheet from Specification_1 now appears inside the UGMaster dataset. 

6. Execute "File > Export >Part" using following options: 
- Part Specification = Existing 
- Specify Part = browse and select Specification_2 
- Drawing Selection = highlight the drawing sheet 
- OK the dialog to proceed with export 

7. Use Display Parent inside Assembly Navigator to make Specification_2 the Work part now. 

8. Activate Part Navigator, and select Second Sheet and perform "Open". This sheet is the sheet coming from Specification_1.



Notes and References


Hardware/Software Configuration

Platform: INTL64
OS: window
OS Version: 764SP1
Product: NX
Application: DRAFTING
Version: V11.0.2
Function: DRAWING/VIEW

Ref: 002-7005202

KB Article ID# PL7005202

Contents

SummaryDetails

Associated Components

Drafting