This KB Article will show you how to automatically map DXF layers to a RF Cell and create a RF Cell
Attachments: | DwgPart2RFPart.efm (116 KB) |
Start Here:
You will need to have imported DXF files into your .pcb design job.
Click on this link to import a DXF file. Importing DXF data into Layout
Once you have imported a DXF file.
In Place mode, move the imported DXF to an open area on the screen.
Drag the attached script file to the middle of the screen. DwgPartRFPPart.efm
Important! Automation Scripts obtained through Knowledge-Base Articles, the Siemens EDA Communities Site, or any resource other than the Siemens Installer, are not supported software. These scripts are written by users and made available for other users as a courtesy. Hence, use with caution and backup your data before executing any such script.
This is an unsupported script and is provided as-is. Please review and test the script thoroughly before deploying it in the Production Environment.
This software or file (the “Material”) contains trade secrets or otherwise confidential information owned by Siemens Industry Software Inc. or its affiliates (collectively, “SISW”), or SISW’s licensors. Access to and use of this information is strictly limited as set forth in one or more applicable agreement(s) with SISW. This Material may not be copied, distributed, or otherwise disclosed without the express written permission of SISW, and may not be used in any way not expressly authorized by SISW.
Unless otherwise agreed in writing, SISW has no obligation to support or otherwise maintain this Material. No representation or other affirmation of fact herein shall be deemed to be a warranty or give rise to any liability of SISW whatsoever.
SISW reserves the right to make changes in specifications and other information contained herein without prior notice, and the reader should, in all cases, consult SISW to determine whether any changes have been made.
SISW MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MATERIAL INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF INTELLECTUAL PROPERTY. SISW SHALL NOT BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL OR PUNITIVE DAMAGES, LOST DATA OR PROFITS, EVEN IF SUCH DAMAGES WERE FORESEEABLE, ARISING OUT OF OR RELATED TO THIS PUBLICATION OR THE INFORMATION CONTAINED IN IT, EVEN IF SISW HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
TRADEMARKS: The trademarks, logos, and service marks (collectively, “Marks”) used herein are the property of Siemens AG, SISW, or their affiliates (collectively, “Siemens”) or other parties. No one is permitted to use these Marks without the prior written consent of Siemens or the owner of the Marks, as applicable. The use herein of third party Marks is not an attempt to indicate Siemens as a source of a product, but is intended to indicate a product from, or associated with, a particular third party. A list of Siemens’ Marks may be viewed at: www.plm.automation.siemens.com/global/en/legal/trademarks.html