Simcenter Micred Power Tester
How to get transient thermal impedance based on the compact model
2024-05-31T02:25:32.000-0400
Simcenter Micred Power Tester
Summary
The operation on how to get transient thermal impedance based on the compact model.
Details
You need to export the Foster or Cauer RC network, here is an example with 4 stages compact network with Rthjc 0.3K/W.
Under T3ster Master Zth plot, pls. clik show button under Setting-Zth-Compact model. You could check if it match with the measurement data at the first section.
Right click on the plot window and choose copy data
Create a new txt file, and paste the Zth response based on the 4 stages network. Now you could deal with the data with your familiar data process tool, such as Excel and so on.