When click File > Check In Actions > Forward Annotation in Xpedition Designer, there is an error message as follows: Error EDM: The operation finished with an error. EdmException: Wrong name (“ForwardAnnotatin”) for container. Container already exists.


Details

When click File > Check In Actions > Forward Annotation in Xpedition Designer, there is an error message as follows:

This is due to user permissions. To resolve this issue, the administrator needs to go to the EDM web and assign user permissions.

1.  In Xpedition EDM Design Cockpit, click Tools > EDM Web.

 

2.  In EDM Web, click on the matrix icon in the top right corner, and select EDM Admin.

 

3. In EDM Admin, click Account Management > Users, select the user and check the Assigned Groups.

4. Click EDM Admin -> Settings -> EDM Design > Data Access Control,click Edit to add the group in Assigned Groups.

5.  As another solution, the administrator can assign the default group“ Design Users" to the user.