When Inner Layer Test Points are used in a Design, the Design should be exported in ODB++ Version 8.
As ODB++ Version 7 does not properly render Inner Layer Test Points, they may show up as "Extra" Netlist Points when running Netlist Analysis.
As such, the Best Practice is to export the Design as ODB++ Version 8, which properly defines and tests Inner Layer Test Points.