Opcenter Execution Electronics IoT - MSS (Valor IoT manufacturing - Shopfloor) Driver can't connect ASM Dek machine

2023-09-27T02:27:16.000-0400
Manufacturing Systems Solutions

Summary

Driver can't connect ASM Dek machine


Details

Driver can't connect ASM Dek machine and report below error.
2023-09-19 19:52:46.839 ERROR [o.s.i.ip.tcp.connection.TcpNioConnection           <io_ocreq_executor-2> ] Exception on Read 127.0.0.1:53904:7281:e837af53-bef9-4d60-92ee-5d28fbb6278e An existing connection was forcibly closed by the remote host
java.io.IOException: An existing connection was forcibly closed by the remote host
    at sun.nio.ch.SocketDispatcher.read0(Native Method)
    at sun.nio.ch.SocketDispatcher.read(SocketDispatcher.java:43)
    at sun.nio.ch.IOUtil.readIntoNativeBuffer(IOUtil.java:223)
    at sun.nio.ch.IOUtil.read(IOUtil.java:197)
    at sun.nio.ch.SocketChannelImpl.read(SocketChannelImpl.java:380)
    at org.springframework.integration.ip.tcp.connection.TcpNioConnection.doRead(TcpNioConnection.java:424)
    at org.springframework.integration.ip.tcp.connection.TcpNioConnection.readPacket(TcpNioConnection.java:497)
    at org.springframework.integration.ip.tcp.connection.AbstractConnectionFactory.lambda$processNioSelections$0(AbstractConnectionFactory.java:691)
    at java.util.concurrent.ThreadPoolExecutor.runWorker(ThreadPoolExecutor.java:1142)
    at java.util.concurrent.ThreadPoolExecutor$Worker.run(ThreadPoolExecutor.java:617)
    at java.lang.Thread.run(Thread.java:745)

For this error, please refer below step to solve this issue.
1. Check the Dek machine 'asmdekeventfolder' share folder permission (Read permission).
2. If this issue still happens when you can access the share folder, please check the 'Event.dat' file size. (you can create a new file with same name when this file size is very big)

KB Article ID# KB000122445_EN_US