Since designs go through multiple cycles, the cell names in the design database could differ from the original cell names with which the waivers were generated and preserved for analysis and validation.

Calibre Auto-Waivers flow provides waiver utility which is useful as it updates the waivers database with the new design database cell names using a mapping file in order to waive the rule check violations successfully. 

In this Support Kit, you will be able to use Calibre Auto-Waivers tools to verify your waiver database on design with updated cell names using waiver_util supported in the auto-waivers flow.

DRC CELL NAME YES CELL SPACE XFORM SVRF statement is required for Auto-waiver runs.

Required license to use Calibre Auto-Waivers for this Support Kit:

  • calwaiver License or calibredrc and calibrehdrc Substitute License

Estimated time to complete the Support Kit: 40 minutes

Version: 2023.3

==================================================

Both Instructions and Demo Data are attached to this article

Instructions: How to Verify Waivers on Designs with Updated Cell Names_000122406.pdf

Demo Data: 000122406.tar.gz

Unpublished work. (c) 2023 Siemens

 

This software or file (the “Material”) contains trade secrets or otherwise confidential information owned by Siemens Industry Software Inc. or its affiliates (collectively, “SISW”), or SISW’s licensors. Access to and use of this information is strictly limited as set forth in one or more applicable agreement(s) with SISW. This Material may not be copied, distributed, or otherwise disclosed without the express written permission of SISW, and may not be used in any way not expressly authorized by SISW.

Unless otherwise agreed in writing, SISW has no obligation to support or otherwise maintain this Material. No  representation or other affirmation of fact herein shall be deemed to be a warranty or  give rise to any liability of SISW whatsoever.

SISW reserves the right to make changes in specifications and  other information contained herein withou tprior notice, and the reader should, in all cases, consult SISW to determine whether any changes have been made.

SISW MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MATERIAL INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF  MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF INTELLECTUAL PROPERTY. SISW SHALL NOT BE LIABLE FOR ANY DIRECT, INDIRECT,INCIDENTAL, CONSEQUENTIAL OR PUNITIVE DAMAGES, LOST DATA OR PROFITS, EVEN IF  SUCH DAMAGES WERE FORESEEABLE, ARISING OUT OF OR RELATED TO THIS PUBLICATION OR THE INFORMATION CONTAINED IN IT, EVEN IF SISW HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.

TRADEMARKS: The trademarks, logos, and service marks (collectively, “Marks”) used herein are the property of Siemens AG, SISW, or their affiliates (collectively, “Siemens”) or other parties. No one is permitted to use these Marks without the prior written consent of Siemens or the owner of the Marks, as applicable. The use herein of third party Marks is not an attempt to indicate Siemens as a source of a product, but is  intended to indicate a product from, or associated with, a particular third party. A list of Siemens’ Marks may be viewed at: www.plm.automation.siemens.com/global/en/legal/trademarks.html

Support Center: support.sw.siemens.com
Send Feedback on Documentation: support.sw.siemens.com/doc_feedback_form

KB Article ID# KB000122406_EN_US

Contents

SummaryDetails

Associated Components

Calibre Auto-Waivers