Opcenter Execution Electronics IoT - MSS (Valor IoT manufacturing - Shopfloor) Test files of SPI/AOI are moved to error folder due to "Test complete time: xxxx cannot be later than the current time: yyyy" error.

2023-08-22T00:32:23.000-0400
Licensing

Summary

Some test files of SPI/AOI are moved to error folder and below error message is recorded. Error Message: Test complete time: Wed Jul 26 16:34:29 GMT+05:30 2023 cannot be later than the current time: Wed Jul 26 16:30:38 GMT+05:30 2023


Details

Symptoms:

Some test files of SPI/AOI are moved to error folder and below error message is recorded.

Error Message: Test complete time: Wed Jul 26 16:34:29 GMT+05:30 2023 cannot be later than the current time: Wed Jul 26 16:30:38 GMT+05:30 2023

Cause:

Above error might occur due to the clock of SPU/DAU which SPI/AOI driver runs doesn't synchronized with a NTP server.

image.png

Solution:

Set correct NTP server (the MSS server is also available if it is configured as a NTP server) to all SPU/DAU boxes to make all clock synchronized
 